Control System

Microprocessor-based Unit Controller is factory mounted, wired and tested to ensure a protection of the Machine and efficient capacity control. The program logic provides proper Start/Stop of the Machine and also enables a communication interface with others.

  • Component Test and Diagnostic Check
  • Touch Screen Interface for Status Display, Set-point Control, and System Configuration
  • Primary and Secondary Status Messages
  • Individual Start/Stop Schedules for Local Mode
  • Recall of Up to 999 Alarm and Alert Messages with Diagnostic Help
  • Extensive Diagnostic and Service Capabilities
  • Advanced Crystallization Protection

Safety Cutouts

  • Solution Pump Motor Overload/High Temperature
  • Refrigerant Pump Motor Overload/High Temperature
  • Low Chilled Water Temperature Cutout
  • Low Refrigerant Temperature Cutout
  • Low Cooling Temperature Cutout
  • Low Chilled Water Flow Cutout
  • Low Cooling Water Flow Cutout (Option)
  • Generator High Temperature Cutout
  • Hot Water High Temperature Cutout (Low Temp. Hot Water Driven type only)
  • High Temperature Generator High Pressure Cutout (Exhaust Gas Driven type only)
  • High Temperature Generator Low Level Cutout (Exhaust Gas Driven type only)

Protective Limits

  • Strong Solution Leaving High Temperature Generator Alarm
  • Hot Water High Temperature Alarm (Low Temp. Hot Water Driven type only)
  • Refrigerant Pump Overload/High Temperature Alarm
  • Solution Pump Motor Overload/High Temperature Alarm
  • Low Refrigerant Temperature Alarm
  • Low Chilled Water Temperature Alarm
  • Low Cooling Water Temperature Alarm
  • Low Chilled Water Flow Alarm

Overrides

  • Hot Water High Temperature (Low Temp. Hot Water Driven type only)
  • Generator Solution High Temperature
  • High Concentration

Temperature Sensor Faults

  • Leaving Chilled Water Temperature
  • Cooling Water Temperature Entering Absorber
  • Refrigerant Condensate Temperature from Condenser
  • Refrigerant Evaporating Temperature
  • Strong Solution Temperature Leaving Generator
  • Entering Hot Water Temperature (Low Temp. Hot Water Driven type only)
  • Exhaust Gas Temperature Cutout (Exhaust Gas Driven type only)

Capacity Control

  • Leaving Chilled Water Control
  • Running Travel Limit (Control Valve Opening Limit)

Indications

  • Chiller Operating Status Message
  • Absorption Cycle State Points
  • Dilution Cycle
  • Power-On
  • Alarm
  • Safety Shutdown Message
  • Run Hours
  • Control Valve Position